RS2000 Series Raman Analyzers
High optical efficiency: Adopts transmission-type spectrometer
High sensitivity: Deep-cooled detector delivering high sensitivity and high signal-to-noise ratio
Flexible operation: Can be coupled with a microscope to realize micro-Raman function
Powerful software: Rich functions including data acquisition, spectral smoothing, noise reduction, spectral subtraction, spectrum matching and quantitative method establishment
Multi-functional sampling accessories: Supplied with solid-sample adapter, liquid-sample adapter and sealed measurement chamber, applicable to samples in solid, powder, liquid and other forms
|
Item |
RS2000Raman Analyzer |
RS2001Raman Analyzer |
RS2002Raman Analyzer |
RS2100Raman Analyzer |
RS2200Raman Analyzer |
|
Feature |
Ultra-high sensitivity |
Cost-effective |
Cost-effective |
Wide applicability |
Ultra-high sensitivity |
|
Laser Excitation Wavelength |
785 ± 0.5 nm |
785 ± 0.5 nm |
785 ± 0.5 nm |
1064 ± 0.5 nm |
532 ± 0.5 nm |
|
Laser Output Power |
Max. 700 mW,continuously adjustable |
Max. 700 mW,continuously adjustable |
Max. 700 mW,continuously adjustable |
Max. 1200 mW,continuously adjustable |
Max. 150 mW,continuously adjustable |
|
Spectral Resolution |
5 cm⁻¹ |
6 cm⁻¹ |
13 cm⁻¹ |
10 cm⁻¹ |
8 cm⁻¹ |
|
Spectral Range |
200 ~ 2600 cm⁻¹ |
220 ~ 2380 cm⁻¹ |
200 ~ 3200 cm⁻¹ |
200 ~ 1880 cm⁻¹ |
230 ~ 4160 cm⁻¹ |
|
Spectrometer Type |
Transmission-type |
Transmission-type |
Reflection-type |
Transmission-type |
Transmission-type |
|
Detector |
-60 °C deep-cooled research-grade thermoelectric cooled area-array CCD |
0 °C cooled detector |
Uncooled detector |
0 °C cooled detector |
-60 °C deep-cooled research-grade thermoelectric cooled area-array CCD |
|
Pixels |
2000 × 256 |
128 × 1044 |
1 × 2048 |
1 × 512 |
2000 × 256 |
|
Number of Detection Channels |
1 (single-channel) |
||||
|
Main Unit Dimension |
496 mm (L) × 312 mm (W) × 185 mm (H) |
||||
|
Main Unit Weight |
≤ 10 kg |
||||
|
Probe |
1 non-immersive fiber-optic probe as standard; other probe models or flow cell optional |
||||
|
Software Functions |
1. Data acquisition; 2. Smart acquisition mode; 3. Modelling; 4. Model validation; 5. Automatic optimization of quantitative models; 6. On-line detection |
||||
|
Communication Interface |
USB 2.0, RS485 expandable |
||||
|
Communication Protocol |
Modbus |
||||
|
Spectral Data Export Format |
csv, txt and other formats available |
||||
|
Power Supply |
100 ~ 240 VAC, 50 ~ 60 Hz |
||||
|
Operating Temperature |
0 ~ 40 °C |
||||
|
Storage Temperature |
-20 ~ 55 °C |
||||
|
Relative Humidity |
0-90% RH |
||||
|
Warm-up Time |
< 5 min |
||||