IC-1000 ion chromatograph is mainly used for the quantification of anions and cations in aqueous solutions. Anions include: fluoride ions, chloride ions, formate ions, acetate ions, bromide ions, nitrate ions, phosphate ions, sulfate ions, etc. Cations include: lithium ions, sodium ions, ammonium ions, potassium ions, magnesium ions, calcium ions, etc.
Solution anions: F-, Cl-, Br-, NO3-, SO42-, PO43-, etc.
Solution cations: Li+, Na+, NH4+, K+, Mg2+, Ca2+, etc.

● Automatic generation of eluent: Can be set and adjusted within the concentration range of 0 - 100 mM
● Continuous suppression of background conductivity: The suppressor is electrolytically self-regenerating, no external acid or alkali is required
● Overall chemical constant temperature: Fast startup stabilization speed and small baseline drift
● Wide detection range and high precision: ppm level, ppb level
● Easy to operate: The human-machine interface is simple and friendly. The "one-button" operation automatically completes parameter determination, sample injection, analysis, calculation, result display, output, etc.
Typical users of IC-1000 ion chromatograph include: environmental monitoring stations, universities (such as chemical engineering colleges, chemistry colleges, biology colleges, analysis and testing centers, etc.), research institutions (related institutions including chemistry, chemical engineering, environmental protection, etc.), petrochemical companies, power stations, metrology institutes, etc.


Measurement object | Lithium, sodium, potassium, rubidium, cesium,chlorine, bromine, iodine, carbonate, nitrate, sulfate The concentration range of carbonate needs to be specified. |
Maximum pressure resistance (MPa) | 42 |
Flow rate range (mL/min) | 0.1-10 |
Flow accuracy (%) | <0.1 |
Flow stability (%) | <0.1 |
Pressure display accuracy (MPa) | 0.1 |
Pressure fluctuation (%) | <0.1 |
Constant temperature range (℃) | 10-70 |
Temperature control accuracy (℃) | ±0.5 |
Baseline noise (μS) | <0.005 |
Washing and rinsing current range (mA) | 0-100 |
Accuracy of eluent current (mA) | 0.1 |
Inhibiting current range (mA) | 0-100 |
Inhibiting current accuracy (mA) | 0.1 |
Linearity | ≥0.99 |
Overall dimensions (mm) | <560x470x650 |
Weight (kg) | 80 |
Power (W) | <300 |
Measurement range | According to requirements |
Measurement accuracy | According to requirements |
Measurement and control software | 1 set |
Dual-plunger constant-flow pump with degassing | 3 sets |
Eluent washing device with ultrapure water bottle | 2 sets |
Filter head | 2 sets |
Degassing device | 2 sets |
Conductivity detector | 2 sets |
Anion separation column | 1 set |
Cation separation column | 1 set |
Anion self-regenerating suppressor | 1 set |
Cation self-regenerating suppressor | 1 set |
Electric six-way valve | 2 sets |
Power cord | 1 set |
Anion standard solution | 1 set |
Cation standard solution | 1 set |
Computer | 1 set |
Printer | 1 set |